Access Virus & Virus TI community since 2002 Virus TI Infekted

Go Back   The Unofficial Access Virus & Virus TI Forum - since 2002 > Discussion concerning Access products > General discussion about Access Virus

General discussion about Access Virus Discussion about Virus A, B, C and TI.

Reply
 
Thread Tools Search this Thread Display Modes
  #1  
Old 25.03.2016, 04:44 PM
Timo's Avatar
Timo Timo is offline
Administrator
This forum member lives here
 
Join Date: 13.07.2003
Location: Kaoss Central, England
Posts: 2,562
Default

Hi, the link to the other thread?

http://infekted.org/virus/showthread.php?t=33471

Ah, seems like ChimneyChop had soft-deleted that support thread, most likely as he solved his query. Never realised he did this. I've undeleted it, as I feel the information is worth keeping for others.

However there's also a similar thread that's been posted recently:-

http://www.infekted.org/virus/showthread.php?t=34157
Reply With Quote
  #2  
Old 07.07.2019, 09:32 AM
unknown_artist unknown_artist is offline
New here
New here
 
Join Date: 07.07.2019
Posts: 5
Default

Hello guys,

I had two dead keys on my Polar... after cleaning the board, one of the dead keys still do not work. I guess, it is needed to replace one pair of that small guys (resistor?). Could anyone confirm if I am wrong or right, please?

Otherwise I may need to exchange the whole board (Silga T120 C 94V0) I assume. But do not have any idea where to get it from.

Many thanks for any advice!
Attached Images
File Type: jpg IMG_4758.jpg (94.2 KB, 5 views)
File Type: jpg IMG_4759.JPG (80.5 KB, 5 views)
Reply With Quote
  #3  
Old 07.07.2019, 03:17 PM
Timo's Avatar
Timo Timo is offline
Administrator
This forum member lives here
 
Join Date: 13.07.2003
Location: Kaoss Central, England
Posts: 2,562
Default

Quote:
Originally Posted by unknown_artist View Post
Hello guys,

I had two dead keys on my Polar... after cleaning the board, one of the dead keys still do not work. I guess, it is needed to replace one pair of that small guys (resistor?). Could anyone confirm if I am wrong or right, please?

Otherwise I may need to exchange the whole board (Silga T120 C 94V0) I assume. But do not have any idea where to get it from.

Many thanks for any advice!
Hi there, your problem could just be the silicone rubber strip that is worn out/torn/damaged, check this first:-

http://infekted.org/virus/showthread...900#post306900

Check the contact on the silicone rubber strip corresponding to the key that is causing you the problems. Look for any tears, or whether the rubber foot for that contact fails to naturally pop back outwards - if the rubber contact stays depressed, or is torn, even slightly, the rubber contact strip for that octave is damaged and needs replacing. It can be easily and cheaply replaced (cost me around £6 per octave). I explain more in the above thread as I had the same problems (one key only transmitted a low velocity, and another key failed to work at all, despite cleaning all the contacts on both the PCB and the rubber strip) and was only identified by viewing the rubber strips closely for damage and obtaining new strips.

As my Indigo is/was approx. 18 years old (has it really been that long?!) I decided to replace all three octaves with three new rubber strips (2x 12-note strips, and 1x 13-note strip) at the same time. Again, more info is in the link above.
__________________
PS > And another thing! Will the Ti|3 have user customisable/importable wavetables? A ribbon-controller or XY-Pad might be nice, too, please! Thanks!
Reply With Quote
  #4  
Old 08.07.2019, 12:45 PM
orx65
 
Posts: n/a
Default

Quote:
Originally Posted by unknown_artist View Post
Hello guys,

I had two dead keys on my Polar... after cleaning the board, one of the dead keys still do not work. I guess, it is needed to replace one pair of that small guys (resistor?). Could anyone confirm if I am wrong or right, please?

Otherwise I may need to exchange the whole board (Silga T120 C 94V0) I assume. But do not have any idea where to get it from.

Many thanks for any advice!
hello
these is crystal diode (germanium) check the image probably all 4 with same measurement.. (i presume )
If you have multimeter , desolder all 4 select diode modality and make the measurement ..if 1 or more is with different value replace.
Attached Images
File Type: jpg diodes.JPG (84.3 KB, 6 views)
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 07:35 PM.
Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Skin Designed by: Talk vBulletin
Copyright ©2002-2022, Infekted.org