I tried everything for some reason it still wont let me modify any of the sysex peramiters. Please help, I do like the layout.
Reply With Quote
  #2  
Old 03.05.2009, 10:51 PM
djflan's Avatar
djflan djflan is offline
Definately caught something...
Very mucho Newbie
 
Join Date: 30.03.2009
Location: Nashville, TN
Posts: 44
Default

I had to modify it on the controller itself...then transmit the template to the program. If you use the template program, sysex strings transmit the value "127" every time. The only was around this is to use the cotroller. Set the byte string for a value, set type to single, set variable byte to 9.
Reply With Quote
  #3  
Old 03.05.2009, 11:04 PM
ShortBus's Avatar
ShortBus ShortBus is offline
Semi Pro
Semi-Pro
 
Join Date: 01.02.2009
Location: Dc, Baltimore Area
Posts: 264
Default

Does that mean I should program the sysex by hand, when i push up on the buttons that normally display the cc numbers it just sais sysex, should it have a string of numbers? I would like to have realtime control over distortions and freqshift. My desktop sits on the desk behind the novi and hardely ever gets touched. I do all my programing with the vc.
Reply With Quote
  #4  
Old 04.05.2009, 02:08 AM
djflan's Avatar
djflan djflan is offline
Definately caught something...
Very mucho Newbie
 
Join Date: 30.03.2009
Location: Nashville, TN
Posts: 44
Default

yes, btw: both of those are already mapped to the controller on page 5 and 6. I had to program all controlls on the midi controller. First you need a utility like Midi-Ox to show what controls from the virus are sending which sysex strings.

Skip to the end now for a simple solution.

for example: Distortion Intensity looks like this as a sysex message
F0 00 20 33 01 10 71 40 65 DV F7

You can ignore F0 and F7, they signify the start and stop portion of the message. We have a string of nine bytes here:
00 20 33 01 10 71 40 65 DV

each two characters represent a value written in hexidecimal. You can ignore the first eight, the tell the synth which parameter we are referring to. Notice the ninth byte, its value is DV. This is a variable byte. So when we turn the distortion intensity knob, the message is sent and DV is replaced with the value (in hex).

To program this on your novation:
1. scroll to the template you wish to edit
2. hold down the edit button and turn or press the control you wish to edit
3. If the control uses sysex values,change control type to sysex.
4. DISPType is what controller displays
5. LoVal is the lowest value this control sends(in decimal here)
6. HighVal is the highest value this control sends(in decimal here)
7. Ports should be left at U1 M1, unless you have a complicated setup
8. Length is length of byte string, excluding string stop and start bytes.
9. DataType is SINGLE, that means we have one variable byte to send
10. DataPsn is position of variable byte, this is always 9 for virus messages.
11. Press up key twice to see byte string
12. Using the example of distortion intensity it should read:
F0 00 20 33 01 10 71 40 65 DV F7
(notice F0 and F7 are always in place because every message needs start and stop.)
13. Now press write twice to write template, the control should now be able to control the synth.



Please note, Unless you dont like the position of the controlls, everything is mapped. You should not have to go through this, I have gone through the trouble of it already....The templates were made to save you from having to do this. To use: connect Novation remote to your computer
upload template pages in order into the controller using the remote template editor I posted. Page 1 needs to be in template spot 1, 2 in 2, etc...
Then connect a midi cable from midi out of your novation into midi in of your virus TI. The novation will now control your TI. To access additional functions on Novation, press the side buttons multiple times.


Hope this helps, Best of luck!
Reply With Quote
  #5  
Old 07.05.2009, 03:48 PM
ehunter ehunter is offline
Definately caught something...
Very mucho Newbie
 
Join Date: 13.04.2009
Posts: 46
Default

So I am not well versed with sysex or midi mapping...Is it easy to implement this? I am looking for a easy to use intuitive template for my remote 37 SL to use with a snow
Reply With Quote
  #6  
Old 07.05.2009, 11:24 PM
djflan's Avatar
djflan djflan is offline
Definately caught something...
Very mucho Newbie
 
Join Date: 30.03.2009
Location: Nashville, TN
Posts: 44
Default

yes, just send the templates to your remote controller and you are set.
Reply With Quote
  #7  
Old 09.05.2009, 06:28 PM
ShortBus's Avatar
ShortBus ShortBus is offline
Semi Pro
Semi-Pro
 
Join Date: 01.02.2009
Location: Dc, Baltimore Area
Posts: 264
Default

Im still having probems with the template. The Strings are correct and in the keyboard but the Ti still dosnt react to anything written in sysex. I have no clue why it works on yours and not mine. I appriciate any help anyone can give me.
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT. The time now is 01:20 PM.
Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Skin Designed by: Talk vBulletin
Copyright ©2002-2022, Infekted.org