View Single Post
  #2  
Old 31.10.2004, 11:54 AM
ben crosland ben crosland is offline
Veteran
Veteran
 
Join Date: 26.08.2003
Posts: 599
Default Re: Input signal starts low....

Quote:
Originally Posted by jasedee
Hi there!

I have commited myself to explore and learn my Virus...but have come across something unusual.

I am sending a 16 bar drum loop to the Virus inputs, and at the beginning of the loop it is VERY low in level, and it gets louder as the loop progresses, until near the end it is at the correct volume....

Im sure it is something I have set incorrectly but cant seem to find this in the manual or in the Virus menu. Is this Input follower?

Thanks for any help!
Check LFO1>Filter Gain - if that isn't the culprit, check the Modmatrix (including LFO1/2 Assigns) for the culprits.

Or as a complete longshot - have you set Input to Dynamic mode, and then triggered it with a midi note every 16 bars? in which case the Amp Attack could be to blame...
Reply With Quote